Shoulder Pain and Disability Index (SPADI)
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
The 13-item SPADI is composed of two subscales which include pain (5 items), and disability (8 items). The scale is a visual analogue scale, ranging from 0-10 cm, with 0 representing "no difficulty (left anchor)" and 10 representing "so difficult required help (right anchor)". The SPADI total score ranges from 0 to 100 and is obtained by averaging the pain and disability subscale scores. Higher scores indicate greater pain and greater disability. The psychometric testing in a previous study has been reported. The Taiwanese version psychometric testing and scoring in a previous study has been reported.
University of Washington- Quality of Life (UW-QOL)
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
University of Washington - Quality of Life (UW-QOL) was characterized of its simplicity and developed to quickly assess head and neck cancer patients' health related QOL. Four versions have been developed since 1993. The current version, UW-QOL version 4 contains 12 items that to assess 12 domains of QOL in head and neck cancer patients. It has been translated into Chinese and tested for its psychometrics in head and neck cancer populations in Taiwan and the 13-item Chinese version (including employment status) of the UWQOL has provided a good reliability and validity.
University of Washington- Quality of Life (UW-QOL)
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
University of Washington - Quality of Life (UW-QOL) was characterized of its simplicity and developed to quickly assess head and neck cancer patients' health related QOL. Four versions have been developed since 1993. The current version, UW-QOL version 4 contains 12 items that to assess 12 domains of QOL in head and neck cancer patients. It has been translated into Chinese and tested for its psychometrics in head and neck cancer populations in Taiwan and the 13-item Chinese version (including employment status) of the UWQOL has provided a good reliability and validity.
Hospital Anxiety and Depression Scale (HADS) - Taiwanese version (HADS-Depression subscale)
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
The 14-item HADS, developed to assess patients' anxiety and depression status, has 7 items that measure anxiety and 7 that measure depression. This scale has been widely used in cancer research to assess patients' psychological distress. The Taiwanese version of HADS has been developed and validated and showed promising psychometrics. In the proposed study, we will use this depression subscale to assess the depression affective dimension of patients' shoulder dysfunction.
Hospital Anxiety and Depression Scale (HADS) - Taiwanese version (HADS-Depression subscale)
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
The 14-item HADS, developed to assess patients' anxiety and depression status, has 7 items that measure anxiety and 7 that measure depression. This scale has been widely used in cancer research to assess patients' psychological distress. The Taiwanese version of HADS has been developed and validated and showed promising psychometrics. In the proposed study, we will use this depression subscale to assess the depression affective dimension of patients' shoulder dysfunction.
Fatigue Symptom Inventory (FSI)
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
We will use the FSI to assess both fatigue intensity (4 items) and fatigue interference (7 items). Psychometric testing of the FSI in cancer patients and healthy subjects showed good validity and reliability. Responses to these items are self-rated on an 11-point Likert-type scale (0=no fatigue at all/no interference; 10=extreme fatigue/extreme interference). The higher the score indicate the greater the levels of fatigue intensity and fatigue interference.
Fatigue Symptom Inventory (FSI)
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
We will use the FSI to assess both fatigue intensity (4 items) and fatigue interference (7 items). Psychometric testing of the FSI in cancer patients and healthy subjects showed good validity and reliability. Responses to these items are self-rated on an 11-point Likert-type scale (0=no fatigue at all/no interference; 10=extreme fatigue/extreme interference). The higher the score indicate the greater the levels of fatigue intensity and fatigue interference.
Background Information
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
Data from self-reported demographics (e.g., age and previous exercise behavior) and medical variables (e.g., cancer type, stage, and operation type) were collected.
Background Information
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
Data from self-reported demographics (e.g., age and previous exercise behavior) and medical variables (e.g., cancer type, stage, and operation type) were collected.
Perceived Barriers of Engaging Exercise
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
One open question to report barrier of engaging exercise.
The Karnofsky Performance Status (KPS)
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
The Karnofsky Performance Status (KPS) scores range from 0 to 100 and has been validated in terms of its reliability and validity.
The Karnofsky Performance Status (KPS)
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
The Karnofsky Performance Status (KPS) scores range from 0 to 100 and has been validated in terms of its reliability and validity.
Muscle strength
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
Using grip strength meter to measure the strength of right and left upper limbs; and will use microFET 2 to measure the strength of bilateral shoulder-muscle strength (shoulder flexion and horizontal abduction) and hip flexor muscle. Both grip strength meter and microFET 2 provided good reliability and validity for measuring muscle strength in the past studies.
Muscle strength
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
Using grip strength meter to measure the strength of right and left upper limbs; and will use microFET 2 to measure the strength of bilateral shoulder-muscle strength (shoulder flexion and horizontal abduction) and hip flexor muscle. Both grip strength meter and microFET 2 provided good reliability and validity for measuring muscle strength in the past studies.
Cervical range of motion (CROM)
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
The CROM was measured by using a "CROM device" (Performance Attainment Associates, St Paul, MN, USA). This CROM device has good reliability and validity. The CROM test evaluates the maximum degrees of neck forward flexion, extension, bilateral lateral flexion (right and left), and bilateral rotation (right and left). The procedure begins with warm-up exercises followed by maintaining a neutral position and moving the head naturally and without pain. Measuring two values and calculating the average.
Cervical range of motion (CROM)
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
The CROM was measured by using a "CROM device" (Performance Attainment Associates, St Paul, MN, USA). This CROM device has good reliability and validity. The CROM test evaluates the maximum degrees of neck forward flexion, extension, bilateral lateral flexion (right and left), and bilateral rotation (right and left). The procedure begins with warm-up exercises followed by maintaining a neutral position and moving the head naturally and without pain. Measuring two values and calculating the average.
Mouth opening
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
The normal range of jaw in HNC patients is 3.5. Past research has shown that vernier caliper is reliable tools for measuring mouth openings. The subjects sat upright and measured the distance between the mandibular incisors and the maxilla without feeling pain. Result expressed in centimeters.
Mouth opening
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
The normal range of jaw in HNC patients is 3.5. Past research has shown that vernier caliper is reliable tools for measuring mouth openings. The subjects sat upright and measured the distance between the mandibular incisors and the maxilla without feeling pain. Result expressed in centimeters.
Title:
SF-12 Health Survey (SF-12)
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
The 12-item SF-12 has eight subscales: physical functioning (2 items), role physical (2 items), role emotional (2 items), mental health (2 items), bodily pain (1 item), general health (1 item), and vitality (1 item), and social functioning (1 item). The SF-12 score include dichotomous items, and three, five-to-six point scales. Each subscale is scored from 0 to 100, with higher scores representing better function.
SF-12 Health Survey (SF-12)
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
The 12-item SF-12 has eight subscales: physical functioning (2 items), role physical (2 items), role emotional (2 items), mental health (2 items), bodily pain (1 item), general health (1 item), and vitality (1 item), and social functioning (1 item). The SF-12 score include dichotomous items, and three, five-to-six point scales. Each subscale is scored from 0 to 100, with higher scores representing better function.
Brief Pain Inventory - Short Form (BPI-S)
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
The BPI-S, a self-report scale used to assess patients' pain experience, consists of two major parts, which measure pain intensity and pain interference. The 4-item pain intensity part measures worst pain intensity, pain intensity on average, least pain intensity, and current pain intensity. The 7-item pain interference part assesses the interference of pain on daily life. Each item is rated on a numerical scale from 0 ("no pain at all" or "no interference at all") to 10 ("worst possible pain I can imagine" for pain intensity or "extremely interfering"). The BPI-S has been found to be a reliable and valid measure of pain experience. The Chinese version of BPI-S has also showed promising psychometric characteristics.
Brief Pain Inventory - Short Form (BPI-S)
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
The BPI-S, a self-report scale used to assess patients' pain experience, consists of two major parts, which measure pain intensity and pain interference. The 4-item pain intensity part measures worst pain intensity, pain intensity on average, least pain intensity, and current pain intensity. The 7-item pain interference part assesses the interference of pain on daily life. Each item is rated on a numerical scale from 0 ("no pain at all" or "no interference at all") to 10 ("worst possible pain I can imagine" for pain intensity or "extremely interfering"). The BPI-S has been found to be a reliable and valid measure of pain experience. The Chinese version of BPI-S has also showed promising psychometric characteristics.
Symptom Severity Scale (SSS)
Phase 1: Change from Baseline (pre-operation) to post-operation 12 months (measured 5 times)
The SSS is a numeric scale that assesses the severity of common symptoms from 0 (no symptom at all) to 10 (as severe as possible), similar to other numeric rating scales of symptom severity. The SSS has been demonstrated as a reliable scale in cancer-related studies in Taiwan, with satisfactory content validity, face validity, and feasibility. The internal consistency reliability (Cronbach's alpha) ranged from .82 to .91.
Symptom Severity Scale (SSS)
Phase 2: Change from Baseline (post-op 1 month) to post-op 6 months (measured 3 times)
The SSS is a numeric scale that assesses the severity of common symptoms from 0 (no symptom at all) to 10 (as severe as possible), similar to other numeric rating scales of symptom severity. The SSS has been demonstrated as a reliable scale in cancer-related studies in Taiwan, with satisfactory content validity, face validity, and feasibility. The internal consistency reliability (Cronbach's alpha) ranged from .82 to .91.